PERFORMANCE SPECIFICATIONS
• Hot DI Water: Filter cartridge will withstand temperatures of 185°F (85°C) for up to 30 consecutive minutes
• Cleaning/Sanitization: Compatible with most common chemical cleaning, sanitizing and sterilizing agents and with
pH range from 1–14 Consult factory for specific compatibility information
• Rinse-Up Volumes: Resistivity rinse-up to 18 MΩ-cm: <30 minutes at a flow of 3 gpm (11 3 lpm) per 10" element
FILTR ATION | SEPAR ATION | PURIFICATION Rinse-up to single digit ppb TOC in <120 minutes at a flow of 3 gpm (11 3 lpm) per 10" element
ZTEC E NOMENCLATURE INFORMATION
ZTEC E Series Filter Retention Nominal End Gasket
™
or O-Ring
Type
Configuration
Rating (microns) Length (inches)
Filter Cartridges ZTEC E 0.03 0.2 –5 * –20 P Double Open End B Buna-N
Series
–9.75
–30
P2
0.45
E
EPDM
226/Flat Single Open End
0.1
–10 –40 P3 222/Flat Single Open End S Silicone
Pleated Polyethersulfone (PES) Membrane P7 226/Fin Single Open End T Teflon encap
for Final Filtration of Ultrapure Water P8 222/Fin Single Open End Viton (O-Rings only)
AM Single Open End, Internal O-Ring T Teflon (gaskets)
Example: ZTEC E 0.45–30P8T NPC Double Open End, Internal O-Ring V Viton
ZTEC E microelectronics grade cartridges represent Graver’s latest devel-
Product Specifications opment in ultrapure water filtration technology The filters are inherently ZTEC E 0 45 –30 P8 T
Media: Asymmetric hydrophilic and contain no added surfactants or wetting agents that could *Available only for DOE (P) configuration
Polyethersulfone Membrane contaminate pure and ultrapure water streams The PES membrane offers
Inner core, end caps, cage: Polypropylene superior flow characteristics, high contaminant capacity and consistent ZTEC E FLOW RATE INTEGRITY TEST SPECIFICATIONS
Support layers: Spunbonded removal of submicron particles The cartridges exhibit rapid rinse-up to
Polypropylene 18 MΩ-cm resistivity and single digit ppb levels of TOC Typical Flow Rate Clean Water at Ambient Temperature Minimum Bubble Point values and maximum
Gaskets/O-Rings: FEATURES & BENEFITS BAR PSI (per 10" cartridge) Diffusive Air Flow (per 10-inch cartridge) values
for ZTEC E filters wet with water:
Buna-N, EPDM, Silicone, Teflon 0 42 6 0 03 µm
Encapsulated Viton O-Rings, • Manufactured, flushed, tested and packaged, in an ISO Class 7 Pore Size Diffusive Air Flow
Teflon (gaskets), Viton Cleanroom Environment 0 30 4 5 0 03 μm ≤ 50 cc/min @ 50 psig (3 1 bar)
Micron ratings: 0 03, 0 1, 0 2, 0 45 µm • Filters are 100% flushed with 18 MΩ-cm DI water and integrity tested 0 1 µm 0 1 μm ≤ 50 cc/min @ 40 psig (2 8 bar)
0 2 µm
Dimensions • Resistivity rinse-up to 18 MΩ-cm and single digit ppb TOC levels Differential Pressure 0 21 3
with minimal throughput 0 2 μm ≤ 35 cc/min @ 30 psig (2 1 bar)
Nominal lengths: 0 10 1 5 0 45 µm
9 75" 10" 20" 30" 40" • Available in a variety of end cap/adapter configurations 0 0 0 45 μm ≤ 35 cc/min @ 20 psig (1 4 bar)
24.8 25.4 50.8 76.2 101.6 cm to fit all industry-standard housings 0 2 4 6 8 USGPM
Outside diameter: 2 7" (6 9 cm) • Pore size, lot and serial number are stamped on each filter 0 7 6 15 1 22 7 30 3 LPM
Inside diameter: 1 0" (2 54 cm) elementfor identification and traceability For liquids other than water, multiply pressure drop by the fluid viscosity in centipoise
Surface area: 7 6 ft (0 7 m ) • Complete qualification guide available
2
2
per 10" element
CERTIFICATIONS
Operating Parameters
ZTEC E filters were tested by outside laboratory, CT Associates in
Maximum sustained
operating temperature: November, 2011 for the following:
176°F (80°C) at 20 psid (1 38 bar) • TOC Rinse-up to 0 5 ppb • Particle Rinse-up
Maximum differential pressure: • Resistivity Rinse-up to 18 MΩ-cm • Trace Metal Extractables
80 psid @ 70°F (5 5 bar @ 21°C) • Non-Volatile Residue • Anion and Cation Extractables
40 psid @ 160°F (2 8 bar @ 71°C)
Maximum reverse differential pressure: Please request Graver ZTEC E Qualification Guide for details and complete
40 psid @ 70°F (2 8 bar @ 21°C) test reports
Recommended change-out pressure: TYPICAL APPLICATIONS
35 psid (2 4 bar) Customer Service/Technical Support: 1-888-353-0303
• DI water Europe (UK): +44-1424-777791 | China: +86-21-5238-6576 | Asia: +65-9671-9966
• High purity chemicals 302-731-1700 | 800-249-1990 | Fax: 1-302-369-0938 | info@gravertech.com | www.gravertech.com