Page 89 - Filter Cartridges Product Catalogue
P. 89

HFH DIMENSIONAL DATA: HORIZONTAL/SWING BOLT  HFH DIMENSIONAL DATA: HORIZONTAL TIPPED (SIDE IN/SIDE OUT, SWING BOLT)

 Rated Flow    2  2  2  Rated Flow                                                     1
 Dim. “E”
 Dim. “D”
 Dim. “F”
                                              Dim. “A”
 Dim. “B”
 Dim. “A”
 Dim. “C”
                                                                                  Dim. “E”
                                                       Dim. “B”
                                                                         Dim. “D”
                                                                Dim. “C”
 Model  Capacity 1    No. 10"   Filter   inches (cm)  inches (cm)  inches (cm)  inches (cm)  inches (cm)  inches (cm)  Max.   Drain  Vent  Gauge  Model  Capacity      No. 10"   Filter   inches (cm)  inches (cm)  inches (cm)  inches (cm)  inches (cm)  Max.   Drain  Vent  Gauge
 GPM (LPM)  Elements  Lengths  Flange  GPM (LPM)  Elements  Lengths                        Flange
 HFH 3H-40  1050 (3975)  3  40  79 3/4" (203)  11 3/4" (30)  61 1/8" (155)  18" (46)  44" (112)  15" (38)  8"  2" NPT  1" NPT  1/4" NPT  HFH 1HT-20  175 (662)  1  20  18" (46)  23 1/2" (60)   8" (20)  16" (41)   40 1/2" (103)  4"  1" NPT  1" NPT  1/4" NPT
 HFH 4H-40  1400 (5300)  4  40  80 1/4" (204)  11 3/4" (30)  61 1/8" (155)  20" (51)  46" (117)  16" (41)  8"  2" NPT  1" NPT  1/4" NPT  HFH 1HT-40  350 (1325)  1  40  18" (46)  30 5/16" (77)  8" (20)  36" (91)  60 1/2" (154)  4"  1" NPT  1" NPT  1/4" NPT
 HFH 7H-40  2450 (9275)  7  40  91 7/8" (233)  15 1/2" (39)  68" (173)  24" (61)  48" (122)  18" (46)  12"  2" NPT  1" NPT  1/4" NPT  HFH 1HT-60  525 (1986)  1  60  18" (46)  37 1/8" (94)  8" (20)  56" (142)  80 1/2" (204)  4"  1" NPT  1" NPT  1/4" NPT
 HFH 1H-60  500 (1893)  1  60  85" (216)  8" (20)  73" (185)  8 5/8" (22)  40" (102)  9" (23)  4"  2" NPT  1" NPT  1/4" NPT  1 Dim  “E” will increase by approx  3" for SS swing
 HFH 3H-60  1500 (5680)  3  60  99 3/4" (253)  11 3/4" (30)  81 1/8" (206)  18" (46)  44" (112)  15" (38)  8"  2" NPT  1" NPT  1/4" NPT
                HFH DIMENSIONAL DRAWING                                 HFH DIMENSIONAL DRAWING
 HFH 4H-60  2000 (7570)  4  60  100 1/4" (255)  11 3/4" (30)  81 1/8" (206)  20" (51)  46" (117)  16" (41)  8"  2" NPT  1" NPT  1/4" NPT
              1-Around Tilted Horizontal Side in/Side out           1-Around Tilted Horizontal Side in/Bottom out
 HFH 7H-60  3500 (13248)  7  60  111 7/8" (284)  15 1/2" (39)  88" (224)  24" (61)  48" (122)  18" (46)  12"  2" NPT  1" NPT  1/4" NPT
                          Swing Bolt Design                                       Swing Bolt Design
 1 Dimensions are based on the maximum connection sizes    2 Dimensions include support legs    3 Dim  “A” will increase by approx  3" for SS swing bolt housings
 HFH DIMENSIONAL DRAWING  HFH DIMENSIONAL DRAWING
                                C                                                     C           E
 Horizontal Swing Bolt Design  Vertical Swing Bolt Design  E
                                          D                                                        D
 A  G
 B  C                                                                         B
                         B
 F  D
                             A
 OVERHEAD CLEARANCE                                                              A
 EQUALS LENGTH OF ELEMENT


 E

 F        HFH DIMENSIONAL DATA: HORIZONTAL TIPPED (SIDE IN/BOTTOM OUT, SWING BOLT)

 A                  Rated Flow   No. 10"   Filter   Dim. “A”   Dim. “B”   Dim. “C”   Dim. “D”   Dim. “E”   1  Max.
 B         Model     Capacity     Elements  Lengths  inches (cm)  inches (cm)  inches (cm)  inches (cm)  inches (cm)  Flange  Drain  Vent  Gauge
 C                  GPM (LPM)
 D
          HFH 1HT-20  175 (662)  1     20     12" (30)   31 15/16" (81)  8" (20)  33 1/2" (85)  45 3/8" (115)   4"  1" NPT  1" NPT  1/4" NPT
          HFH 1HT-40  350 (1325)  1    40     12" (30)   38 3/4" (98)   8" (20)  53 1/2" (136)  65 3/8" (166)  4"  1" NPT  1" NPT  1/4" NPT
 E
          HFH 1HT-60  525 (1986)  1    60     12" (30)  45 5/8" (116)  8" (20)  73 1/2" (187)  85 3/8" (217)   4"  1" NPT  1" NPT  1/4" NPT
        1 Dim  “E” will increase by approx  3" for SS swing bolt housings


 HFH DIMENSIONAL DATA: VERTICAL/SWING BOLT

 Rated Flow  No. 10"   2  2  2  2
 Model  Capacity 1     Ele-  Filter   Dim. “A”   Dim. “B”   Dim. “C”  Dim. “D”   Dim. “E”   Dim. “F”   Dim. “G”    Max.   Drain  Vent  Gauge
 in (cm)
 in (cm)
 in (cm)
 in (cm)
 in (cm)
 in (cm)
 in (cm)
 GPM (LPM)  ments  Lengths  Flange
 HFH 1V-20  175 (662)  1  20  51 7/8" (132)  48" (122)  40" (102)  28" (71)  12" (30)  8 5/8" (22)  18" (46)  4"  2" NPT  1" NPT  1/4" NPT
 HFH 3V-20  525 (1986)  3  20  63 5/8" (162)  56 3/4" (144)  45" (114)  28" (71)  12" (30)  18" (46)  30" (76)  8"  2" NPT  1" NPT  1/4" NPT
 HFH 1V-40  350 (1325)  1  40  71 7/8" (183)  68" (173)  60" (152)  48" (122)  12" (30)  8 5/8" (22)  18" (46)  4"  2" NPT  1" NPT  1/4" NPT
 HFH 3V-40  1050 (3975)  3  40  83 5/8" (212)  76 3/4" (195)  65" (165)  48" (122)  12" (30)  18" (46)  30" (76)  8"  2" NPT  1" NPT  1/4" NPT
 HFH 4V-40  1400 (5300)   4  40  84 1/8" (214)  76 3/4" (195)  65" (165)  48" (122)  12" (30)  20" (51)  32" (81)  8"  2" NPT  1" NPT  1/4" NPT
 HFH 7V-40  2450 (9275)  7  40  95 7/8" (244)  87 1/2" (222)  72" (183)  52" (132)  12" (30)  24" (61)  36" (91)  12"  2" NPT  1" NPT  1/4" NPT
        Customer Service/Technical Support: 1-888-353-0303
 1 Dimensions are based on the maximum connection sizes    2 Dimensions include support legs    3 Dim  “A” will increase by approx  3" for SS swing bolt housings   Europe (UK): +44-1424-777791  |  China: +86-21-5238-6576  |  Asia: +65-9671-9966
        302-731-1700  |  800-249-1990  |  Fax: 1-302-369-0938  |  info@gravertech.com  |  www.gravertech.com