Page 11 - Filter Cartridges Product Catalogue
P. 11
TefTEC NOMENCLATURE INFORMATION
Filter Retention Nominal End Gasket
Type Rating (microns) Length (in) Configuration or O-Ring Options
TefTEC 0.05 0.45 –5 –20 P Double Open End B Buna-N –W Pre-
FILTR ATION | SEPAR ATION | PURIFICATION Series 0.1 1 –9.75 * –30 P2 226/Flat Single Open End E EPDM Wet
0.2 –10 –40 P3 222/Flat Single Open End S Silicone
P7 226/Fin Single Open End T Teflon encap
TefTEC Series P8 222/Fin Single Open End Viton (O-Rings
™
only)
Single Open End, Internal O-Ring
AM
Filter Cartridges Example: TefTEC 0.1–20P2S–W NPC Double Open End, Internal O-Ring T Teflon (gaskets)
V Viton
TefTEC 0 1 –20 P2 S –W
Absolute Rated PTFE Membrane *Available only for DOE (P) configuration
Filter Cartridges TefTEC FLOW RATE INTEGRITY TEST SPECIFICATIONS
Typical Flow Rate Clean Water at Ambient Air Diffusion per 10-inch cartridge wet with 60/40
TefTEC cartridge filters are constructed with naturally hydrophobic PTFE
membrane and polypropylene support layers and components The Temperature (per 10" cartridge) IPA/water. Contact Graver Technologies for specific method.
BAR PSI
Product Specifications HIMA retentive PTFE membrane offers superior hydrophobicity and water 0 28 4 Pore Size Specification
Media: Expanded PTFE Membrane intrusion resistance compared to PVDF and polypropylene membranes, 0 05 μm ≤ 50 cc/min @ 22 psig (1 5 bar)
Inner core, end caps, cage: Polypropylene and the cartridge construction offers a cost-effective alternative to 0 21 3 0 05 µm 0 1 μm ≤ 50 cc/min @ 18 psig (1 2 bar)
Support layers: Polypropylene all-fluorocarbon filters TefTEC filters are ideal for gas/vent applications Differential Pressure 0 14 2 0 1 µm
Gaskets/O-Rings: and the filtration of aggressive chemicals and solvents 0 2 µm 0 2 μm ≤ 35 cc/min @ 12 psig (0 8 bar)
Buna-N, EPDM, Silicone, Teflon FEATURES & BENEFITS 0 07 1 0 45 µm 0 45 μm ≤ 15 cc/min @ 5 psig (0 34 bar)
Encapsulated Viton (O-Rings only), 1 0 µm
Teflon (gaskets), Viton • High surface area, single-layer construction provides superior 0 0 1 0 μm ≤ 15 cc/min @ 3 psig (0 2 bar)
Micron ratings: 0 05, 0 1, 0 2, 0 45, 1 0 µm flow rates and minimizes filtration system size 0 2 4 6 8 USGPM
• 100% Flushed with 18 MΩ-cm DI water and integrity tested 0 7 6 15 1 22 7 30 3 LPM
Dimensions • Filters are manufactured, flushed, tested and packaged For liquids other than water, multiply pressure drop by the fluid viscosity in centipoise TefTEC AIR FLOW RATE
Nominal lengths: in an ISO Class 7 Cleanroom Environment Air Flow Rate (per 10" cartridge)
5" 9 75" 10" 20" 30" 40" • Each filter element stamped with pore size, lot and serial
12.7 24.8 25.4 50.8 76.2 101.6 cm number for identification and traceability TefTEC AIR FLOW RATE BAR PSI 0 05,
Outside diameter: 2 7" (6 9 cm) • Complete qualification guide available Air Flow Rate (per 10" cartridge) 0 042 0 6 0 1 µm
Inside diameter: 1 0" (2 54 cm) • Available prewet for use with aqueous based chemicals 0 035 0 5 0 2 µm
BAR
Surface area: 8 5 ft (0 79 m ) 0 062 PSI 0 05, 0 028 0 4
2
2
0 9
per 10" element CERTIFICATIONS 0 8 0 1 µm Differential Pressure 0 021 0 3
0 2 µm
Operating Parameters • USP Class VI: Meets USP Class VI Biological Test for Plastics 0 048 0 7 0 014 0 2 0 45 µm
0 6
1 0 µm
Maximum operating temperature: • FDA Listed Materials: All materials comply with FDA Title 21 of the Code of Differential Pressure 0 034 0 5 0 007 0 1
203°F (95°C) Federal Regulations Sections 174 5, 177 1520, and 177 1550 as applicable for 0 021 0 4 0 45 µm 0 0 0 5 10 15 20 25 30 35 40 45 50 SCFM
0 3
Maximum differential pressure: food and beverage contact 0 2 1 0 µm 3
80 psid @ 70°F (5 5 bar @ 21°C) 0 007 0 1 0 17 34 51 68 85 M /HR
40 psid @ 160°F (2 8 bar @ 71°C) TYPICAL APPLICATIONS 0 0 0 5 10 15 20 25 30 35 40 45 50 SCFM Test conditions: System pressure at 30 psig, 65°F (18°C)
Maximum reverse differential pressure: • Aggressive chemicals • Compressed gases • Pharmaceutical
3
40 psid @ 70°F (2 8 bar @ 21°C) • Strong acids/bases • Photoresists Intermediates 0 17 34 51 68 85 M /HR
Recommended change-out pressure: • Solvents • Hot DI water • Fermentation air Test conditions: System pressure at <10 psig (vent), 65°F (18°C), outlet open to atmosphere
35 psid (2 4 bar)
• Tank Vents
PERFORMANCE SPECIFICATIONS Customer Service/Technical Support: 1-888-353-0303
• Steam/Autoclave: Cartridges will withstand at least 100 steam/autoclave Europe (UK): +44-1424-777791 | China: +86-21-5238-6576 | Asia: +65-9671-9966
thirty-minute cycles @ 275°F (135°C) 302-731-1700 | 800-249-1990 | Fax: 1-302-369-0938 | info@gravertech.com | www.gravertech.com
| 5 | | 6 |